| Server IP : 78.140.185.180 / Your IP : 216.73.216.168 Web Server : LiteSpeed System : Linux cpanel13.v.fozzy.com 4.18.0-513.11.1.lve.el8.x86_64 #1 SMP Thu Jan 18 16:21:02 UTC 2024 x86_64 User : builderbox ( 1072) PHP Version : 7.3.33 Disable Function : NONE MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : ON | Sudo : OFF | Pkexec : OFF Directory : /proc/self/root/proc/thread-self/root/usr/share/snmp/mibs/ |
Upload File : |
LM-SENSORS-MIB DEFINITIONS ::= BEGIN
--
-- Derived from the original VEST-INTERNETT-MIB. Open issues:
--
-- (a) where to register this MIB?
-- (b) use not-accessible for diskIOIndex?
--
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
ucdExperimental
FROM UCD-SNMP-MIB;
lmSensorsMIB MODULE-IDENTITY
LAST-UPDATED "200011050000Z"
ORGANIZATION "AdamsNames Ltd"
CONTACT-INFO
"Primary Contact: M J Oldfield
email: m@mail.tc"
DESCRIPTION
"This MIB module defines objects for lm_sensor derived data."
REVISION "200011050000Z"
DESCRIPTION
"Derived from DISKIO-MIB ex UCD."
::= { lmSensors 1 }
lmSensors OBJECT IDENTIFIER ::= { ucdExperimental 16 }
--
lmTempSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of temperature sensors and their values."
::= { lmSensors 2 }
lmTempSensorsEntry OBJECT-TYPE
SYNTAX LMTempSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmTempSensorsIndex }
::= { lmTempSensorsTable 1 }
LMTempSensorsEntry ::= SEQUENCE {
lmTempSensorsIndex Integer32,
lmTempSensorsDevice DisplayString,
lmTempSensorsValue Gauge32
}
lmTempSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmTempSensorsEntry 1 }
lmTempSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the temperature sensor we are reading."
::= { lmTempSensorsEntry 2 }
lmTempSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of this sensor in mC."
::= { lmTempSensorsEntry 3 }
--
lmFanSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMFanSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of fan sensors and their values."
::= { lmSensors 3 }
lmFanSensorsEntry OBJECT-TYPE
SYNTAX LMFanSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmFanSensorsIndex }
::= { lmFanSensorsTable 1 }
LMFanSensorsEntry ::= SEQUENCE {
lmFanSensorsIndex Integer32,
lmFanSensorsDevice DisplayString,
lmFanSensorsValue Gauge32
}
lmFanSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmFanSensorsEntry 1 }
lmFanSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the fan sensor we are reading."
::= { lmFanSensorsEntry 2 }
lmFanSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The rotation speed of the fan in RPM."
::= { lmFanSensorsEntry 3 }
--
lmVoltSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMVoltSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of voltage sensors and their values."
::= { lmSensors 4 }
lmVoltSensorsEntry OBJECT-TYPE
SYNTAX LMVoltSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmVoltSensorsIndex }
::= { lmVoltSensorsTable 1 }
LMVoltSensorsEntry ::= SEQUENCE {
lmVoltSensorsIndex Integer32,
lmVoltSensorsDevice DisplayString,
lmVoltSensorsValue Gauge32
}
lmVoltSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmVoltSensorsEntry 1 }
lmVoltSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the device we are reading."
::= { lmVoltSensorsEntry 2 }
lmVoltSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage in mV."
::= { lmVoltSensorsEntry 3 }
--
lmMiscSensorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LMMiscSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of miscellaneous sensor devices and their values."
::= { lmSensors 5 }
lmMiscSensorsEntry OBJECT-TYPE
SYNTAX LMMiscSensorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing a device and its statistics."
INDEX { lmMiscSensorsIndex }
::= { lmMiscSensorsTable 1 }
LMMiscSensorsEntry ::= SEQUENCE {
lmMiscSensorsIndex Integer32,
lmMiscSensorsDevice DisplayString,
lmMiscSensorsValue Gauge32
}
lmMiscSensorsIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reference index for each observed device."
::= { lmMiscSensorsEntry 1 }
lmMiscSensorsDevice OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the device we are reading."
::= { lmMiscSensorsEntry 2 }
lmMiscSensorsValue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this sensor."
::= { lmMiscSensorsEntry 3 }
END