����JFIF��x�x����'
Server IP : 78.140.185.180 / Your IP : 18.224.5.46 Web Server : LiteSpeed System : Linux cpanel13.v.fozzy.com 4.18.0-513.11.1.lve.el8.x86_64 #1 SMP Thu Jan 18 16:21:02 UTC 2024 x86_64 User : builderbox ( 1072) PHP Version : 7.3.33 Disable Function : NONE MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : ON | Sudo : OFF | Pkexec : OFF Directory : /opt/dell/srvadmin/etc/srvadmin-storage/ |
Upload File : |
;-------------------------------------------------------------------- ; ; Dell Inc. PROPRIETARY INFORMATION ; This software is supplied under the terms of a license agreement or ; non-disclosure agreement with Dell Inc. and may not be copied or ; disclosed except in accordance with the terms of that agreement. ; ; Copyright (c) 1995-2022 Dell Inc. ; All Rights Reserved. ; ;-------------------------------------------------------------------- ; General settings [general] ; Amount, in seconds, to sleep between each attempt to poll the PV20x, PV21x, and PV22x enclosure(s). EnclosurePollingInterval=30 ; nonDellCertified flag for blocking all non-dell certified alerts. NonDellCertifiedFlag=yes ; Amount, in seconds, to delay at init before attempting to poll the PV20x, PV21x, and PV22x enclosure(s). EnclosurePollingInitialDelay=30 ; Number of failed attempts to communicate with enclosure before an alert is generated. EnclosureCommunicationLostCount=6 ; Enable/disable array disk auto-initializing (Adaptec only). AdaptecAutoInitializeArrayDisks=Off ; Enable/disable dcomsm.log at startup of the Systems Management Data Manager. Debug=Off ; Debug Levels in a comma separated list in this order Queue, Ral, Val, AFAVIL, LSIVIL, NRSVIL, EVIL, SASVIL, SASEVIL, HEL, SWRVIL, PSRVIL, RNAVIL, GSMVIL ; DebugLevels will cause all debug data tagged at that level or lower (a level of 3 or higher is the most verbose) ; Debug Level 0 = CRITICAL debug data only ; Debug Level 1 = CRITICAL_INFO ; Debug Level 2 = DEBUG ; Debug Level 3 = INFO DebugLevels=0,0,0,0,0,0,0,0,0,0,0,0,0,0 ;autolog settings ; order tty emm Autologfilecount=14,5 ;Thread stack size limit on esx4i in Kbs ThreadStackSize=512 ; Enable/disable the firmware and driver version check at startup of the Systems Management Data Manager. DepCheck=On NRSDepCheck=On ; Enable/disable smart enclosure shutdown - applies to all attached enclosures. SmartThermalShutdown=Off ; Set RRRWE Threshold for SSDs - SAS/SATA and PCIe SSDs. RRWEThresholdSasSata=0 RRWEThresholdPCIe=0 ; Set Available Spare Threshold for PCIe SSDs. AvailableSpareWarningThresholdPCIe=10 AvailableSpareCriticalThresholdPCIe=5 SmartAlertPollInterval=1 ; Enable/disable initialization of Windows(tm) volumes during virtual disk initialization (LSI only). EraseWinVolinInitVD=on ; Alert log name AlertLogName=smalerts.xml ; Amount, in seconds, to sleep after a failed SCSI passthru call (LSI only). MegaPassthruRetrySleep=2 ; Number of attempts to successfully issue a SCSI passthru call (LSI only). MegaPassthruAttempts=3 ; Amount, in minutes, to sleep between refresh of SNMP cached data. SNMPRefreshMinutes=5 ; Enable/disable detection and alert of device problems during Initialization DetectAndAlert=On ; Amount, in minutes to call the discovery of all VIL's, If 0 then discovery should not happen. ; Minimum minutes to be assigned is 60 minutes(1 hour). ; Note: 60 minutes x 24 hours = 1440 minutes(Recommended value for auto discover is 24 hours) VilDiscoverIntervalInMinutes=1440 ; Startup logic Control ReportOnStart=On DebugSNMP=Off [sasvil] ; Amount, in seconds, to wait at shutdown for running commands to complete. TerminateCommandCompleteTimeout=10 ; Amount, in seconds, to wait for "create virtual disk" to resolve the new disk to an OS disk. VDtoOSCorrelationTimeout=30 ; Timeout, in milliseconds, for starting threads involved in event notification. ThreadStartTimeout=60000 ; Time, in seconds, to delay before callback if a function fails to set a value. BtmDelayTime=5 ; Startup Event Notification Control ReportStartUpEvents=On ; Startup Alert Control ReportAlertsOnStart=On ; SMART alert Polling interval Control for SAS Adapters/Controllers (10 minutes) SmartIRPollInterval=600 ; SMART Alert reminder interval in seconds ( Default: 24 hours/ 86400s) for SAS Adapters/Controllersss SmartIRRemindInterval=86400 [Multipath] [ProtectionPolicies] RAID1=0,0 RAID5=0,0 RAID6=0,0 RAID10=0,0 RAID50=0,0 RAID60=0,0 RAIDALL=0,0 GHS=0,0 IncludeGHSinVDstate=0 ; Libraries to be loaded at startup of the Systems Management Data Manager, in order, beginning with entry 0. [loadvils] vil4=dsm_sm_sasvil vil5=dsm_sm_sasenclvil vil6=dsm_sm_swrvil vil7=dsm_sm_psrvil vil9=dsm_sm_gsmvil [SSDSmartInterval] DAY=1 [VendorID] Marvell=9 MarvellNVMe=10 storelib8=11 [VendorLibName] Windows_9=mv_api Linux_9=libmvraid Windows_10=BossNvme Linux_10=libBossNvme Windows_11=storelib8 Linux_11=libstorelib8 [DependentVendorLibName] 11=HAPI